Greg  Ferro

SDN Is Business, OpenFlow Is Technology

Software-defined networking (SDN) and OpenFlow aren’t the same thing. We’ll clarify the technical differences and discuss a more important distinction: SDN emphasizes applications that drive network usability and business requirements, while OpenFlow is a technology to link an SDN controller and network devices.

Many people don't understand the difference between OpenFlow and software-defined networking (SDN). This isn't surprising because the two technologies are closely related. However, they aren't interchangeable. OpenFlow is protocol that configures network switches using a process like an API. SDN is a term that describes providing programmable interfaces within a network infrastructure to enable a high degree of automation in provisioning network services. The SDN term is being abused by marketers who want to apply it to a wide range of technologies.

In fact, SDN can be explicitly defined. There are three architectural layers to an SDN network: the physical network, the SDN applications and the SDN controller. Let's look at each.

More Insights

Webcasts

More >>

White Papers

More >>

Reports

More >>

Physical Network. The lowest layer consists of the physical devices in your network that form the foundation of all IT infrastructure. We use the term "switch" because OpenFlow changes the way Ethernet switches work. For this article, you can also consider virtual switches part of the physical infrastructure.

SDN Applications. The most visible layer in an SDN design is the applications that deliver services, such as switch/network virtualization, firewalls and flow balancers. (Note that OpenFlow-based load balancers are called flow balancers. They aren't traditional load balancers because they can't read packet contents.) These applications are similar to or the same as those in use today where the software runs on dedicated hardware. Most of the coming innovation in networking will occur in SDN applications.

SDN Controller. The SDN controller is the middleware that serves as the linchpin of the entire architecture. The controller must integrate with all the physical and virtual devices in the network. The controller abstracts the physical network devices from the SDN software that works with those devices. There is a high degree of integration between the controller and network devices. In an OpenFlow environment, the controller will use the OpenFlow protocol and the NETCONF protocol to communicate with switches. (OpenFlow is the API for sending flow data to the switch, and NETCONF is the network configuration API).

SDN: Basic Architecture
SDN: Basic Architecture

In current SDN approaches, vendors provide applications and a controller in a single product. For example, Nicira/VMware packages its applications and controller into a single proprietary application stack. Cisco will package its controller into the OnePK product by embedding the controller in IOS software on the devices. I also expect Cisco to deliver a master controller in the near future. Big Switch Networks, which recently launched the commercial version of its SDN controller, offers two applications that run on the controller: Big Virtual Switch and Big Tap.

Clearly the controller is a key element in the network architecture. It must present APIs to the applications that represents usable functions, and it's here that the battle for SDN dominance will be fiercest among the vendors.

SDN APIs: The New Battleground

An SDN architecture has two distinct networking APIs: northbound and southbound. OpenFlow is a southbound API. OpenFlow describes an industry-standard API that configures the frame-forwarding silicon in an Ethernet switch and defines the flow path through a network. In addition, the Open Networking Foundation (ONF), the standards body overseeing the OpenFlow protocol, announced an API for device configuration called OF-CONFIG. OF-CONFIG uses the NETCONF XML data format to define the language.

Cisco's OnePK is also a southbound API. There is much discussion around whether OpenFlow is enough to meet all the needs of networking, especially with regards to migrating from a packet-based network to a flow-based network. There are unresolved issues that will hinder that migration, such as the need for interoperability with existing protocols such as STP and OSPF.

SDN: Basic Architecture
Northbound and Southbound APIs

The northbound API provides a mechanism in an SDN architecture to present services or applications to the business. Each application will develop a view of the flow tables for network devices and then send requests to the controller for distribution to the network devices.

For example, a virtual switching application would build a network graph/database of all points in the network of physical and virtual switches. In a multitenant Ethernet network, the app would develop a set of flow rules that emulate Ethernet VLANs while maintaining full isolation for each tenant's flows. The flow rules would consist of values based on ingress and egress ports, plus the source and destination MAC address.

Next page: API uncertainty

 1 | 2  | Next Page »


Related Reading



Network Computing encourages readers to engage in spirited, healthy debate, including taking us to task. However, Network Computing moderates all comments posted to our site, and reserves the right to modify or remove any content that it determines to be derogatory, offensive, inflammatory, vulgar, irrelevant/off-topic, racist or obvious marketing/SPAM. Network Computing further reserves the right to disable the profile of any commenter participating in said activities.

 
Disqus Tips To upload an avatar photo, first complete your Disqus profile. | Please read our commenting policy.
 

Editor's Choice

Research: 2014 State of Server Technology

Research: 2014 State of Server Technology

Buying power and influence are rapidly shifting to service providers. Where does that leave enterprise IT? Not at the cutting edge, thatís for sure: Only 19% are increasing both the number and capability of servers, budgets are level or down for 60% and just 12% are using new micro technology.
Get full survey results now! »

Vendor Turf Wars

Vendor Turf Wars

The enterprise tech market used to be an orderly place, where vendors had clearly defined markets. No more. Driven both by increasing complexity and Wall Street demands for growth, big vendors are duking it out for primacy -- and refusing to work together for IT's benefit. Must we now pick a side, or is neutrality an option?
Get the Digital Issue »

WEBCAST: Software Defined Networking (SDN) First Steps

WEBCAST: Software Defined Networking (SDN) First Steps


Software defined networking encompasses several emerging technologies that bring programmable interfaces to data center networks and promise to make networks more observable and automated, as well as better suited to the specific needs of large virtualized data centers. Attend this webcast to learn the overall concept of SDN and its benefits, describe the different conceptual approaches to SDN, and examine the various technologies, both proprietary and open source, that are emerging.
Register Today »

Related Content

From Our Sponsor

How Data Center Infrastructure Management Software Improves Planning and Cuts Operational Cost

How Data Center Infrastructure Management Software Improves Planning and Cuts Operational Cost

Business executives are challenging their IT staffs to convert data centers from cost centers into producers of business value. Data centers can make a significant impact to the bottom line by enabling the business to respond more quickly to market demands. This paper demonstrates, through a series of examples, how data center infrastructure management software tools can simplify operational processes, cut costs, and speed up information delivery.

Impact of Hot and Cold Aisle Containment on Data Center Temperature and Efficiency

Impact of Hot and Cold Aisle Containment on Data Center Temperature and Efficiency

Both hot-air and cold-air containment can improve the predictability and efficiency of traditional data center cooling systems. While both approaches minimize the mixing of hot and cold air, there are practical differences in implementation and operation that have significant consequences on work environment conditions, PUE, and economizer mode hours. The choice of hot-aisle containment over cold-aisle containment can save 43% in annual cooling system energy cost, corresponding to a 15% reduction in annualized PUE. This paper examines both methodologies and highlights the reasons why hot-aisle containment emerges as the preferred best practice for new data centers.

Monitoring Physical Threats in the Data Center

Monitoring Physical Threats in the Data Center

Traditional methodologies for monitoring the data center environment are no longer sufficient. With technologies such as blade servers driving up cooling demands and regulations such as Sarbanes-Oxley driving up data security requirements, the physical environment in the data center must be watched more closely. While well understood protocols exist for monitoring physical devices such as UPS systems, computer room air conditioners, and fire suppression systems, there is a class of distributed monitoring points that is often ignored. This paper describes this class of threats, suggests approaches to deploying monitoring devices, and provides best practices in leveraging the collected data to reduce downtime.

Cooling Strategies for Ultra-High Density Racks and Blade Servers

Cooling Strategies for Ultra-High Density Racks and Blade Servers

Rack power of 10 kW per rack or more can result from the deployment of high density information technology equipment such as blade servers. This creates difficult cooling challenges in a data center environment where the industry average rack power consumption is under 2 kW. Five strategies for deploying ultra-high power racks are described, covering practical solutions for both new and existing data centers.

Power and Cooling Capacity Management for Data Centers

Power and Cooling Capacity Management for Data Centers

High density IT equipment stresses the power density capability of modern data centers. Installation and unmanaged proliferation of this equipment can lead to unexpected problems with power and cooling infrastructure including overheating, overloads, and loss of redundancy. The ability to measure and predict power and cooling capability at the rack enclosure level is required to ensure predictable performance and optimize use of the physical infrastructure resource. This paper describes the principles for achieving power and cooling capacity management.