Data Center Efficiency Plateaus

A recent survey shows that efficiency is no longer a major priority for data center operators. Meanwhile, public cloud and DCIM software are on the rise.

The latest Uptime Institute Data Center Industry Survey reveals some interesting trends, including a reduced focus on data center efficiency.

According to Uptime's survey, which queried 1,000 data center facilities operators, IT managers and senior executives from around the globe, efficiency as measured by median responses (so we're not talking about behemoths like Amazon, Google or Facebook), has plateaued and is no longer considered an urgent priority. Only half of North American respondents said they considered efficiency to be very important.

More Insights

Webcasts

More >>

White Papers

More >>

Reports

More >>

Uptime's data shows that initial gains in PUE, the standard metric for data center efficiency, which improved dramatically from 2007 to 2011, were largely the result of easy fixes like properly isolating hot and cold aisles, installing blanking panels in unused rack segments and upgrading old power distribution equipment to more efficient models. Now, however, improvements are much harder and more costly to come by. Thus, most operators consider a 1.65 PUE (the average in this year's survey) good enough, even as the mega colocation centers and cloud operators race to see who can edge closer to the ideal level of 1.0.

An easy fix can be borrowed from every homeowner trying to cut their summer electric bill: just crank up the thermostat. Only 7% of respondents operate data centers at temperatures above 75 degrees, even though ASHRAE, the professional society of HVAC engineers, says 80 degrees is a reasonable upper bound.

Another drag on efficiency is the prevalence of zombie servers, the survey indicated. "According to Uptime Institute’s estimates based on industry experience, around 20% of servers in data centers today are obsolete, outdated or unused," the report said. Uptime estimates that for every 1U zombie unplugged, operators save about $2,500 a year in energy, OS licenses and hardware maintenance.

[Uptime's study also indicated that data centers are becoming the domain of service providers as smaller enterprises increasingly outsource their data center operations. Read Kurt Marko's analysis in "Data Center Study: The Big Get Bigger."]

In addition to data center efficiency trends, the Uptime report highlights three data center technologies that are poised for explosive growth: adoption of public cloud services, data center infrastructure management (DCIM) and prefab modular data centers. While we'd agree on the first two, we have our doubts about modulars.

Public cloud growth is a no-brainer as nearly every survey, including ours, shows that enterprise resistance, fueled by a combination of protectionism, security and performance FUD and immature management software, is rapidly crumbling. Only 20% of the respondents to InformationWeek's State of Cloud Computing Survey have no plans to use a cloud service provider. Uptime finds global cloud adoption still rather low at 28%, but large companies are twice as likely as smaller ones (as defined by the total number of operated servers) to deploy public cloud services.

In contrast, private cloud seems to have hit a brick wall, with deployment actually falling in Uptime's survey. It's either harder than people think or smaller companies figure why bother re-architecting for a private cloud when they can rent a ready-made one at AWS or Rackspace.

According to the survey, 38% of respondents use DCIM software, which Uptime defines as a facility-wide system that catalogs assets, collects usage statistics and records operational status. Using some homegrown spreadsheets and open source monitoring tools doesn't qualify, although we would argue that something like Nagios is a long way from DIY Perl scripting and includes many DCIM features. Uptime's number seems high, but the respondent demographics skew large, with 82% managing more than one site and 42% in the business of data center hosting as a colocation or cloud service provider.

Of course, only large operators can justify the cost of DCIM tools; looking at just the small companies in Uptime's sample, 72% report spending over $100,000 on DCIM tools, while 17% of the largest ones spend $400,000 or more.

I take issue with Uptime's prediction regarding prefab modular data centers. Those semi-truck shipping containers made into a tightly packed computer rooms are a clever idea that's time has come and gone. When first introduced more than five years ago, modulars offered superior energy and space efficiency to conventional facilities, but with some significant downsides. First, you needed to redesign data center facilities to look more like a mobile home park -- with concrete pads and utility drops -- than a self-contained warehouse. Secondly, with such tight quarters, if -- or make that when -- a modular's cooling system ever so much as hiccups, the temperature spike could roast everything within minutes.

According to Uptime's own data, modular adoption is tepid with only 8% of data center operators having deployed and another 8% considering them. The majority of respondents (53%), have no interest. Even among large operators, only 15% have modular deployments.



Related Reading



Network Computing encourages readers to engage in spirited, healthy debate, including taking us to task. However, Network Computing moderates all comments posted to our site, and reserves the right to modify or remove any content that it determines to be derogatory, offensive, inflammatory, vulgar, irrelevant/off-topic, racist or obvious marketing/SPAM. Network Computing further reserves the right to disable the profile of any commenter participating in said activities.

 
Disqus Tips To upload an avatar photo, first complete your Disqus profile. | Please read our commenting policy.
 

Editor's Choice

Research: 2014 State of Server Technology

Research: 2014 State of Server Technology

Buying power and influence are rapidly shifting to service providers. Where does that leave enterprise IT? Not at the cutting edge, thatís for sure: Only 19% are increasing both the number and capability of servers, budgets are level or down for 60% and just 12% are using new micro technology.
Get full survey results now! »

Vendor Turf Wars

Vendor Turf Wars

The enterprise tech market used to be an orderly place, where vendors had clearly defined markets. No more. Driven both by increasing complexity and Wall Street demands for growth, big vendors are duking it out for primacy -- and refusing to work together for IT's benefit. Must we now pick a side, or is neutrality an option?
Get the Digital Issue »

WEBCAST: Software Defined Networking (SDN) First Steps

WEBCAST: Software Defined Networking (SDN) First Steps


Software defined networking encompasses several emerging technologies that bring programmable interfaces to data center networks and promise to make networks more observable and automated, as well as better suited to the specific needs of large virtualized data centers. Attend this webcast to learn the overall concept of SDN and its benefits, describe the different conceptual approaches to SDN, and examine the various technologies, both proprietary and open source, that are emerging.
Register Today »

Related Content

From Our Sponsor

How Data Center Infrastructure Management Software Improves Planning and Cuts Operational Cost

How Data Center Infrastructure Management Software Improves Planning and Cuts Operational Cost

Business executives are challenging their IT staffs to convert data centers from cost centers into producers of business value. Data centers can make a significant impact to the bottom line by enabling the business to respond more quickly to market demands. This paper demonstrates, through a series of examples, how data center infrastructure management software tools can simplify operational processes, cut costs, and speed up information delivery.

Impact of Hot and Cold Aisle Containment on Data Center Temperature and Efficiency

Impact of Hot and Cold Aisle Containment on Data Center Temperature and Efficiency

Both hot-air and cold-air containment can improve the predictability and efficiency of traditional data center cooling systems. While both approaches minimize the mixing of hot and cold air, there are practical differences in implementation and operation that have significant consequences on work environment conditions, PUE, and economizer mode hours. The choice of hot-aisle containment over cold-aisle containment can save 43% in annual cooling system energy cost, corresponding to a 15% reduction in annualized PUE. This paper examines both methodologies and highlights the reasons why hot-aisle containment emerges as the preferred best practice for new data centers.

Monitoring Physical Threats in the Data Center

Monitoring Physical Threats in the Data Center

Traditional methodologies for monitoring the data center environment are no longer sufficient. With technologies such as blade servers driving up cooling demands and regulations such as Sarbanes-Oxley driving up data security requirements, the physical environment in the data center must be watched more closely. While well understood protocols exist for monitoring physical devices such as UPS systems, computer room air conditioners, and fire suppression systems, there is a class of distributed monitoring points that is often ignored. This paper describes this class of threats, suggests approaches to deploying monitoring devices, and provides best practices in leveraging the collected data to reduce downtime.

Cooling Strategies for Ultra-High Density Racks and Blade Servers

Cooling Strategies for Ultra-High Density Racks and Blade Servers

Rack power of 10 kW per rack or more can result from the deployment of high density information technology equipment such as blade servers. This creates difficult cooling challenges in a data center environment where the industry average rack power consumption is under 2 kW. Five strategies for deploying ultra-high power racks are described, covering practical solutions for both new and existing data centers.

Power and Cooling Capacity Management for Data Centers

Power and Cooling Capacity Management for Data Centers

High density IT equipment stresses the power density capability of modern data centers. Installation and unmanaged proliferation of this equipment can lead to unexpected problems with power and cooling infrastructure including overheating, overloads, and loss of redundancy. The ability to measure and predict power and cooling capability at the rack enclosure level is required to ensure predictable performance and optimize use of the physical infrastructure resource. This paper describes the principles for achieving power and cooling capacity management.