Shingled Magnetic Recording Part 1: How SMR Expands Disk Drive Capacity

Disk drive vendors have a new technique to increase disk density. Here's how it works.

Despite predictions every few years that we’ve reached some physical limit, the semiconductor industry has managed to double the transistor density of its products every two years, as predicted by Moore’s Law. For many years, disk drive bit density doubled every two years following Kryder’s Law, but recently drive vendors have been struggling to produce the ever bigger disks we as users demand. Their latest trick is to overlap disk tracks in a technology known as Shingled Magnetic Recording (SMR).

The growth in disk drive bit density has stalled as the bits written using the current technology known as perpendicular recording have gotten close enough to the superparamagnetic limit of the magnetic media on the drive that there can’t be any significant further advancements beyond the 1Tbit/in2 of today’s disk drives.

The superparamagnetic limit is the point where the individual magnetic domains on the disk are so small that they no longer reliably hold data, in part because of the influence of adjacent bits that may be magnetized in the opposite direction.

One way to squeeze more data onto a given area is to change the magnetic media to one that has a higher coercivity, which is one that requires a stronger magnetic field to switch from facing north to facing south. Using magnetically stiffer materials reduces the minimum size of a bit before the super paramagnetic limit raises its ugly head, but it also requires a more powerful magnetic field to flip those stiffer bits.

The problem the drive designers face is that they can’t focus the stronger magnetic field into narrow enough tracks to pack more data on a disk. Their solution is to partially overlap, or shingle, the tracks as they write them to the disk.

Shingling lets vendors cram more tracks in the same space, eliminating the guard bands that separate tracks on a more conventional disk. After data is written to track 1, the head moves a fraction of a track over and writes track 2.

[Read why Howard Marks thinks spinning disks will still be the better bargain through 2020 despite falling SSD prices in "SSDs Cheaper Than Hard Drives? Not In This Decade."]

Since the drive can read the narrow exposed portion of each track, shingled drives read data pretty much the same as conventional drives. The problem comes when an application tries to randomly write to a track that’s already been partially overwritten by the next shingled track. Where a conventional drive can just move the heads back to track 54 and rewrite sector 17, if you tried that on a shingled drive you’d wipe out sector 17 on tracks 55 and 56 as well.

For some applications, such as Facebook’s cold storage where disk drives are essentially WORM (write once, read many) devices, we could just shingle tracks across the entire surface of the disk. The application would just have to know that it can write sequentially and then read randomly. However, if we’re going take advantage of the additional capacity shingled tracks give us for more general use, just shingling all the tracks isn’t going to be the right solution.

While dedicated disk drives for deep archives would be interesting, the drive vendors have figured out a way to make shingled drives a more general solution. I’ll look at how in my next post.



Related Reading


More Insights



Network Computing encourages readers to engage in spirited, healthy debate, including taking us to task. However, Network Computing moderates all comments posted to our site, and reserves the right to modify or remove any content that it determines to be derogatory, offensive, inflammatory, vulgar, irrelevant/off-topic, racist or obvious marketing/SPAM. Network Computing further reserves the right to disable the profile of any commenter participating in said activities.

 
Disqus Tips To upload an avatar photo, first complete your Disqus profile. | Please read our commenting policy.
 

Editor's Choice

Research: 2014 State of Server Technology

Research: 2014 State of Server Technology

Buying power and influence are rapidly shifting to service providers. Where does that leave enterprise IT? Not at the cutting edge, thatís for sure: Only 19% are increasing both the number and capability of servers, budgets are level or down for 60% and just 12% are using new micro technology.
Get full survey results now! »

Vendor Turf Wars

Vendor Turf Wars

The enterprise tech market used to be an orderly place, where vendors had clearly defined markets. No more. Driven both by increasing complexity and Wall Street demands for growth, big vendors are duking it out for primacy -- and refusing to work together for IT's benefit. Must we now pick a side, or is neutrality an option?
Get the Digital Issue »

WEBCAST: Software Defined Networking (SDN) First Steps

WEBCAST: Software Defined Networking (SDN) First Steps


Software defined networking encompasses several emerging technologies that bring programmable interfaces to data center networks and promise to make networks more observable and automated, as well as better suited to the specific needs of large virtualized data centers. Attend this webcast to learn the overall concept of SDN and its benefits, describe the different conceptual approaches to SDN, and examine the various technologies, both proprietary and open source, that are emerging.
Register Today »

Related Content

From Our Sponsor

How Data Center Infrastructure Management Software Improves Planning and Cuts Operational Cost

How Data Center Infrastructure Management Software Improves Planning and Cuts Operational Cost

Business executives are challenging their IT staffs to convert data centers from cost centers into producers of business value. Data centers can make a significant impact to the bottom line by enabling the business to respond more quickly to market demands. This paper demonstrates, through a series of examples, how data center infrastructure management software tools can simplify operational processes, cut costs, and speed up information delivery.

Impact of Hot and Cold Aisle Containment on Data Center Temperature and Efficiency

Impact of Hot and Cold Aisle Containment on Data Center Temperature and Efficiency

Both hot-air and cold-air containment can improve the predictability and efficiency of traditional data center cooling systems. While both approaches minimize the mixing of hot and cold air, there are practical differences in implementation and operation that have significant consequences on work environment conditions, PUE, and economizer mode hours. The choice of hot-aisle containment over cold-aisle containment can save 43% in annual cooling system energy cost, corresponding to a 15% reduction in annualized PUE. This paper examines both methodologies and highlights the reasons why hot-aisle containment emerges as the preferred best practice for new data centers.

Monitoring Physical Threats in the Data Center

Monitoring Physical Threats in the Data Center

Traditional methodologies for monitoring the data center environment are no longer sufficient. With technologies such as blade servers driving up cooling demands and regulations such as Sarbanes-Oxley driving up data security requirements, the physical environment in the data center must be watched more closely. While well understood protocols exist for monitoring physical devices such as UPS systems, computer room air conditioners, and fire suppression systems, there is a class of distributed monitoring points that is often ignored. This paper describes this class of threats, suggests approaches to deploying monitoring devices, and provides best practices in leveraging the collected data to reduce downtime.

Cooling Strategies for Ultra-High Density Racks and Blade Servers

Cooling Strategies for Ultra-High Density Racks and Blade Servers

Rack power of 10 kW per rack or more can result from the deployment of high density information technology equipment such as blade servers. This creates difficult cooling challenges in a data center environment where the industry average rack power consumption is under 2 kW. Five strategies for deploying ultra-high power racks are described, covering practical solutions for both new and existing data centers.

Power and Cooling Capacity Management for Data Centers

Power and Cooling Capacity Management for Data Centers

High density IT equipment stresses the power density capability of modern data centers. Installation and unmanaged proliferation of this equipment can lead to unexpected problems with power and cooling infrastructure including overheating, overloads, and loss of redundancy. The ability to measure and predict power and cooling capability at the rack enclosure level is required to ensure predictable performance and optimize use of the physical infrastructure resource. This paper describes the principles for achieving power and cooling capacity management.