Will SDN Kill TRILL?

Layer 2 multipathing standards such as TRILL and SPB may seem redundant in an SDN world. But these standards still have a role to play while we wait to see how the SDN market matures.

In recent years, a great deal of time has gone into developing standards--including TRILL, SPB and DCB--that enable Layer 2 multipathing and improve Ethernet's capabilities in the virtualized data center. These standards promise to enable all links to forward traffic, eliminate loops and create meshes to let traffic take the shortest path between switches.

Much digital ink has been spilled over use cases and the pros and cons of these approaches. Vendors have rolled out products, working groups have exchanged ideas, and engineers have tried to sort out just what is going on.

More Insights

Webcasts

More >>

White Papers

More >>

Reports

More >>

Now, software-defined networking (SDN) has leaped into the pool and caused lots of waves with its promise to upend traditional network design and operation. To paraphrase a question put to me on Twitter, is there a future for data center Ethernet standards such as TRILL in an SDN world? If so, how do the standards fit? If not, how will SDN recreate the promised functionality?

There's an assumption built into the question that must be explored. The assumption is that the networks of the world are going to be software defined. And by "software defined," I mean, at the least, a network whose forwarding behavior is programmed by a central controller with a holistic view of the network topology.

I believe it's possible that this is where networks are going, but even if I'm right, that transition is going to take years. SDN is in its early stages. Startups are coming out of stealth with their notion of what SDN is and what problems it can solve. Most SDN products target specific use cases and are definitely not one-size-fits-all. The OpenFlow specification, which is a core component of the centralized controller model of SDN, is running ahead of the capabilities of currently available silicon to perform all potential matching operations in hardware.

Meanwhile, big vendors are feeling out the market, determining what customers actually want out of SDN, and developing products based around those requirements. At the same time, they are working toprotect their vested interests.

If SDN ubiquity is years away, is there a fit for the emergent data center Ethernet standards? Yes, clearly.

While SDN can offer Layer 2 multipathing in the data center, is that why you should be shopping for SDN products? Not really. Customers can deploy Cisco Nexus switches with FabricPath, Brocade VDX switches with VCS, Juniper QFX switches with QFabric, or Avaya switches with VENA (to name a few approaches). They can build a Layer 2 data center topology that works like a Layer 3 routing topology. Those fabric technologies are comparatively mature and scale effectively without too much design effort, though they do require a homogenous data center network.

So why should you be shopping for SDN? Consider the following points.

[Ethan Banks is a featured speaker at Interop Las Vegas this May, including the conference session "Chopping Down the Fat Tree in the Small Data Center." Register here today.]

--Centralized controllers learn about multiple paths through the network between a given source and destination, and can create multiple forwarding entries the network switches can use to deliver traffic across multiple paths.

--ECMP and MLAG creation is a relatively trivial task for a central controller with a holistic view of the network, as there is no great distinction to be made between physical devices.

--A centralized network view makes it possible to engineer end-to-end paths for data to follow based on policies defined by a network engineer, such as latency and hop count, and not merely source and destination addresses.

In other words, because a central controller sees the network as a whole, there's no need for distributed protocols to determine a loop-free, best-path topology. An individual switch no longer has to figure out for itself how to get to a remote destination; the switch is told how to forward by the controller. "Best path" can mean whatever a network designer wants it to mean, and not what a group of protocol designers decided it meant in an RFC.

Does that mean data centers can get rid of TRILL and SPB? Think in terms of domain to answer that question. How many switches are under the central controller? What sorts of forwarding controls are required? How much of that functionality is available in silicon, and what impact does that have on switching performance? What mechanism is used to connect to other switching domains? Data center SDN doesn't have answers to all of these questions yet, and so it's hard to predict the long-term role for TRILL and SPB in the data center.

That said, in my opinion, TRILL and SPB have an immediate role to play in the data center. These are well-documented technologies with reference architectures you can buy today with support in silicon from many vendors. Assuming a service life of five to seven years for network gear, TRILL and SPB are positioned to serve you well for the duration. However, the long view of L2 multipathing is that as OpenFlow performance improves in lockstep with OpenFlow-capable silicon, forwarding techniques using OpenFlow could conceivably displace TRILL and SPB as an L2 multipathing technology.



Related Reading



Network Computing encourages readers to engage in spirited, healthy debate, including taking us to task. However, Network Computing moderates all comments posted to our site, and reserves the right to modify or remove any content that it determines to be derogatory, offensive, inflammatory, vulgar, irrelevant/off-topic, racist or obvious marketing/SPAM. Network Computing further reserves the right to disable the profile of any commenter participating in said activities.

 
Disqus Tips To upload an avatar photo, first complete your Disqus profile. | Please read our commenting policy.
 

Editor's Choice

Research: 2014 State of Server Technology

Research: 2014 State of Server Technology

Buying power and influence are rapidly shifting to service providers. Where does that leave enterprise IT? Not at the cutting edge, thatís for sure: Only 19% are increasing both the number and capability of servers, budgets are level or down for 60% and just 12% are using new micro technology.
Get full survey results now! »

Vendor Turf Wars

Vendor Turf Wars

The enterprise tech market used to be an orderly place, where vendors had clearly defined markets. No more. Driven both by increasing complexity and Wall Street demands for growth, big vendors are duking it out for primacy -- and refusing to work together for IT's benefit. Must we now pick a side, or is neutrality an option?
Get the Digital Issue »

WEBCAST: Software Defined Networking (SDN) First Steps

WEBCAST: Software Defined Networking (SDN) First Steps


Software defined networking encompasses several emerging technologies that bring programmable interfaces to data center networks and promise to make networks more observable and automated, as well as better suited to the specific needs of large virtualized data centers. Attend this webcast to learn the overall concept of SDN and its benefits, describe the different conceptual approaches to SDN, and examine the various technologies, both proprietary and open source, that are emerging.
Register Today »

Related Content

From Our Sponsor

How Data Center Infrastructure Management Software Improves Planning and Cuts Operational Cost

How Data Center Infrastructure Management Software Improves Planning and Cuts Operational Cost

Business executives are challenging their IT staffs to convert data centers from cost centers into producers of business value. Data centers can make a significant impact to the bottom line by enabling the business to respond more quickly to market demands. This paper demonstrates, through a series of examples, how data center infrastructure management software tools can simplify operational processes, cut costs, and speed up information delivery.

Impact of Hot and Cold Aisle Containment on Data Center Temperature and Efficiency

Impact of Hot and Cold Aisle Containment on Data Center Temperature and Efficiency

Both hot-air and cold-air containment can improve the predictability and efficiency of traditional data center cooling systems. While both approaches minimize the mixing of hot and cold air, there are practical differences in implementation and operation that have significant consequences on work environment conditions, PUE, and economizer mode hours. The choice of hot-aisle containment over cold-aisle containment can save 43% in annual cooling system energy cost, corresponding to a 15% reduction in annualized PUE. This paper examines both methodologies and highlights the reasons why hot-aisle containment emerges as the preferred best practice for new data centers.

Monitoring Physical Threats in the Data Center

Monitoring Physical Threats in the Data Center

Traditional methodologies for monitoring the data center environment are no longer sufficient. With technologies such as blade servers driving up cooling demands and regulations such as Sarbanes-Oxley driving up data security requirements, the physical environment in the data center must be watched more closely. While well understood protocols exist for monitoring physical devices such as UPS systems, computer room air conditioners, and fire suppression systems, there is a class of distributed monitoring points that is often ignored. This paper describes this class of threats, suggests approaches to deploying monitoring devices, and provides best practices in leveraging the collected data to reduce downtime.

Cooling Strategies for Ultra-High Density Racks and Blade Servers

Cooling Strategies for Ultra-High Density Racks and Blade Servers

Rack power of 10 kW per rack or more can result from the deployment of high density information technology equipment such as blade servers. This creates difficult cooling challenges in a data center environment where the industry average rack power consumption is under 2 kW. Five strategies for deploying ultra-high power racks are described, covering practical solutions for both new and existing data centers.

Power and Cooling Capacity Management for Data Centers

Power and Cooling Capacity Management for Data Centers

High density IT equipment stresses the power density capability of modern data centers. Installation and unmanaged proliferation of this equipment can lead to unexpected problems with power and cooling infrastructure including overheating, overloads, and loss of redundancy. The ability to measure and predict power and cooling capability at the rack enclosure level is required to ensure predictable performance and optimize use of the physical infrastructure resource. This paper describes the principles for achieving power and cooling capacity management.