Cisco continued its product announcements at Cisco Live this week with the Nexus 7700 switch family, and Dynamic Fabric Automation, an architecture for creating a network fabric that supports physical and virtual environments and streamlines switch configuration and management.

Cisco says it has more than 40,000 Nexus 7000 chassis in the field. Now it has two more switches to add to the 7000 family with the Nexus 7700 line. The 7700 has a maximum throughput of 83 Tbps, and a single system can have up to 384 40-GigE ports or 192 100-GigE ports. As with other switches in the 7000 line, the 7700s will include dual redundant supervisor modules to enable software upgrades without losing packets. The 7700 line will come in two versions: a 10-slot 7710 and an 18-slot 7718. Cisco says the chassis will be available in July.

More Insights

Webcasts

More >>

White Papers

More >>

Reports

More >>

Cisco also announced new F3 I/O modules for the 7000 series, including 24-port 40-GigE and 12-port 100-GigE line cards for the 7700 and 12-port 40-Gig line cards for the other switches in the 7000 series. The F3 module supports MPLS, VPLS, FabricPath, LISP and OTV natively. The F3 modules are expected to ship in the fourth quarter of this year.

[Nexus isn't the only Cisco hardware to get new products. The company also announced a new entry in its Catalyst family. Get the details in "Cisco Catalyst 6800: Same Game, New Name."]

It's been a good quarter for muscular switches. This May, Arista's new 7500E data center switch won the Best of Interop award in part due to its specs, including a 30-Tbps backplane. The 7500E supports 10-, 40- and 100-GigE ports, and boasts sub-4 μsec latency within a chassis.

Cisco also announced the Dynamic Fabric Automation (DFA) architecture, a fabric designed to unify physical and virtual switching and support east-west traffic. DFA is built around a spine-and-leaf concept using Nexus hardware. The spine is a distributed backplane, and every leaf node connects to every spine switch.

According to Cisco, no physical or virtual machine will be more than two hops from any other. Cisco also says that DFA will support power-on provisioning, so that when a new network device is added to the fabric, it can grab a configuration from a pre-defined template.

As you might imagine, DFA requires a variety of Cisco products to implement. The fabric is managed with Cisco's Data Center Network Manager (DCNM) 7.0, which acts as a central console where administrators can provision individual devices as well as create common configurations for groups or types of devices.

DFA also requires the use of FabricPath for multipathing and loop prevention. On the hardware side, the fabric is built around the Nexus family, including the 5000s in the spine and 6000s and 7000s as leaf or spine nodes. On the virtual side, customers will need to deploy the Nexus 1000v. More details are available here.



Related Reading



Network Computing encourages readers to engage in spirited, healthy debate, including taking us to task. However, Network Computing moderates all comments posted to our site, and reserves the right to modify or remove any content that it determines to be derogatory, offensive, inflammatory, vulgar, irrelevant/off-topic, racist or obvious marketing/SPAM. Network Computing further reserves the right to disable the profile of any commenter participating in said activities.

 
Disqus Tips To upload an avatar photo, first complete your Disqus profile. | Please read our commenting policy.
 

Editor's Choice

Research: 2014 State of Server Technology

Research: 2014 State of Server Technology

Buying power and influence are rapidly shifting to service providers. Where does that leave enterprise IT? Not at the cutting edge, thatís for sure: Only 19% are increasing both the number and capability of servers, budgets are level or down for 60% and just 12% are using new micro technology.
Get full survey results now! »

Vendor Turf Wars

Vendor Turf Wars

The enterprise tech market used to be an orderly place, where vendors had clearly defined markets. No more. Driven both by increasing complexity and Wall Street demands for growth, big vendors are duking it out for primacy -- and refusing to work together for IT's benefit. Must we now pick a side, or is neutrality an option?
Get the Digital Issue »

WEBCAST: Software Defined Networking (SDN) First Steps

WEBCAST: Software Defined Networking (SDN) First Steps


Software defined networking encompasses several emerging technologies that bring programmable interfaces to data center networks and promise to make networks more observable and automated, as well as better suited to the specific needs of large virtualized data centers. Attend this webcast to learn the overall concept of SDN and its benefits, describe the different conceptual approaches to SDN, and examine the various technologies, both proprietary and open source, that are emerging.
Register Today »

Related Content

From Our Sponsor

How Data Center Infrastructure Management Software Improves Planning and Cuts Operational Cost

How Data Center Infrastructure Management Software Improves Planning and Cuts Operational Cost

Business executives are challenging their IT staffs to convert data centers from cost centers into producers of business value. Data centers can make a significant impact to the bottom line by enabling the business to respond more quickly to market demands. This paper demonstrates, through a series of examples, how data center infrastructure management software tools can simplify operational processes, cut costs, and speed up information delivery.

Impact of Hot and Cold Aisle Containment on Data Center Temperature and Efficiency

Impact of Hot and Cold Aisle Containment on Data Center Temperature and Efficiency

Both hot-air and cold-air containment can improve the predictability and efficiency of traditional data center cooling systems. While both approaches minimize the mixing of hot and cold air, there are practical differences in implementation and operation that have significant consequences on work environment conditions, PUE, and economizer mode hours. The choice of hot-aisle containment over cold-aisle containment can save 43% in annual cooling system energy cost, corresponding to a 15% reduction in annualized PUE. This paper examines both methodologies and highlights the reasons why hot-aisle containment emerges as the preferred best practice for new data centers.

Monitoring Physical Threats in the Data Center

Monitoring Physical Threats in the Data Center

Traditional methodologies for monitoring the data center environment are no longer sufficient. With technologies such as blade servers driving up cooling demands and regulations such as Sarbanes-Oxley driving up data security requirements, the physical environment in the data center must be watched more closely. While well understood protocols exist for monitoring physical devices such as UPS systems, computer room air conditioners, and fire suppression systems, there is a class of distributed monitoring points that is often ignored. This paper describes this class of threats, suggests approaches to deploying monitoring devices, and provides best practices in leveraging the collected data to reduce downtime.

Cooling Strategies for Ultra-High Density Racks and Blade Servers

Cooling Strategies for Ultra-High Density Racks and Blade Servers

Rack power of 10 kW per rack or more can result from the deployment of high density information technology equipment such as blade servers. This creates difficult cooling challenges in a data center environment where the industry average rack power consumption is under 2 kW. Five strategies for deploying ultra-high power racks are described, covering practical solutions for both new and existing data centers.

Power and Cooling Capacity Management for Data Centers

Power and Cooling Capacity Management for Data Centers

High density IT equipment stresses the power density capability of modern data centers. Installation and unmanaged proliferation of this equipment can lead to unexpected problems with power and cooling infrastructure including overheating, overloads, and loss of redundancy. The ability to measure and predict power and cooling capability at the rack enclosure level is required to ensure predictable performance and optimize use of the physical infrastructure resource. This paper describes the principles for achieving power and cooling capacity management.